AXIS#.WS.TDELAY4

Description

AXIS#.WS.TDELAY4 defines the delay time after first current-pulse injection.

Versions

Action Version Notes
Implemented 02-00-00-000

General Information

Type

Read/Write

Units

ms

Range

0 to 10,000 ms

Default Value

2000 ms

Data Type

Integer

Stored in Non-Volatile Memory

Yes

Variants Supported

All variants are supported.

Industrial Ethernet Information

EtherCAT CoE and CANopen

Command

Index

SubIndex

Data Type

Units

Float Scale

Access

PDO Mappable

AXIS1.WS.TDELAY1

5013h

05h

Unsigned8

-

-

Read/Write

No

AXIS1.WS.TDELAY2

5013h

06h

Unsigned8

-

-

Read/Write

No

AXIS1.WS.TDELAY3

5013h

07h

Unsigned16

-

-

Read/Write

No

AXIS1.WS.TDELAY4

5013h

08h

Unsigned16

-

-

Read/Write

No

AXIS2.WS.TDELAY1

5113h

05h

Unsigned8

-

-

Read/Write

No

AXIS2.WS.TDELAY2

5113h

06h

Unsigned8

-

-

Read/Write

No

AXIS2.WS.TDELAY3

5113h

07h

Unsigned16

-

-

Read/Write

No

AXIS2.WS.TDELAY4

5113h

08h

Unsigned16

-

-

Read/Write

No

EtherNet/IP

ID

Instance

Attribute

Name

Data Type

Access

User Mappable

6708

1

6708 (0x1a34)

AXIS1.WS.TDELAY1

Unsigned8

Read/Write

Yes

72244

2

6708 (0x1a34)

AXIS2.WS.TDELAY1

Unsigned8

Read/Write

Yes

6709

1

6709 (0x1a35)

AXIS1.WS.TDELAY2

Unsigned8

Read/Write

Yes

72245

2

6709 (0x1a35)

AXIS2.WS.TDELAY2

Unsigned8

Read/Write

Yes

6710

1

6710 (0x1a36)

AXIS1.WS.TDELAY3

Unsigned16

Read/Write

Yes

72246

2

6710 (0x1a36)

AXIS2.WS.TDELAY3

Unsigned16

Read/Write

Yes

6714

1

6714 (0x1a3a)

AXIS1.WS.TDELAY4

Unsigned16

Read/Write

Yes

72250

2

6714 (0x1a3a)

AXIS2.WS.TDELAY4

Unsigned16

Read/Write

Yes

PROFINET

Parameter

PNU

Data Type

Access

Units

AXIS#.WS.TDELAY1

6708

Unsigned8

Read/Write

-

AXIS#.WS.TDELAY2

6709

Unsigned8

Read/Write

-

AXIS#.WS.TDELAY3

6710

Unsigned16

Read/Write

-

AXIS#.WS.TDELAY4

6714

Unsigned16

Read/Write

-